MSL-rated components can stay out of dry packaging only for the floor life defined by their moisture sensitivity level, which ranges from unlimited at MSL 1 to just 4 hours at MSL 6. Floor life is the time a part may be exposed to factory ambient conditions, normally 30 °C and 60% relative humidity or lower, before it must be soldered or returned to dry storage. Always check the label on the moisture barrier bag, because it states the MSL and the peak reflow temperature the rating applies to. The sections below cover how floor life is counted, the limits per level, what to do after an overrun, and how to store partially used reels.
How is floor life counted once the bag is opened?
Floor life starts the moment the moisture barrier bag is opened, or when the parts are otherwise exposed to ambient air, and runs until they are soldered or placed back in controlled dry storage. The clock keeps running through machine setup, waiting time and idle periods on the pick-and-place machine, not only during active placement.
In practice, the count covers the whole time a component sits outside a bag with a sealed desiccant. That includes the time on a feeder, a reel left on a shelf, or a board that has been populated on one side and is waiting for the second reflow pass. The floor life rating applies to conditions at or below 30 °C and 60% RH. In hotter or more humid workshops, moisture is absorbed faster than the label assumes, so treat the printed limit as a maximum rather than a target.
A few habits keep the count reliable:
- Write the date and time of opening on the bag or reel label.
- Check the humidity indicator card when the bag is opened. If it shows readings above the limit printed on the card, the parts may already have absorbed moisture and need baking before use.
- Record cumulative exposure if a reel is opened, used and resealed several times. The exposure time adds up across sessions unless the parts have been properly baked to reset it.
What are the floor life limits for each MSL level?
Floor life limits under J-STD-033 at 30 °C and 60% RH or below are: MSL 1 unlimited, MSL 2 one year, MSL 2a four weeks, MSL 3 168 hours, MSL 4 72 hours, MSL 5 48 hours, MSL 5a 24 hours and MSL 6 time on label (TOL), typically 6 hours or less.
- MSL 1: unlimited floor life, no dry packaging required for moisture reasons.
- MSL 2: 1 year.
- MSL 2a: 4 weeks.
- MSL 3: 168 hours (7 days).
- MSL 4: 72 hours.
- MSL 5: 48 hours.
- MSL 5a: 24 hours.
- MSL 6: mandatory bake before use, then reflow within the time on the label.
Two points matter for prototype work. First, many fine-pitch BGAs, QFNs and larger ICs sit at MSL 3 or higher, so a one-week limit is easy to exceed when a design waits for a second revision or a missing part. Second, the MSL rating is tied to a specific peak reflow temperature. Lead-free processes run hotter, and a rating given for a lower peak temperature does not automatically carry over. The datasheet and bag label remain the authority for each part.
What happens if components exceed their floor life?
Components that exceed their floor life may have absorbed enough moisture to be damaged during reflow. Trapped moisture turns to steam as the package heats, which can cause delamination, internal cracking or popcorning. The part may still pass visual inspection and even a first electrical test, but its long-term reliability is no longer assured.
The failure mechanism is straightforward. Plastic packages absorb water vapour from the air over time. In a reflow oven, the temperature rises faster than that moisture can diffuse out, so internal pressure builds. The consequences include:
- Popcorning, where the package bulges or cracks audibly.
- Internal delamination between the die, lead frame and moulding compound.
- Wire bond damage or lifted die attach, which may only show up as intermittent faults later.
Because some of this damage is invisible, the correct response to an exceeded floor life is not to reflow and hope. Either bake the parts according to J-STD-033 to remove the absorbed moisture and reset the floor life, or replace them. For critical prototypes, replacement is often cheaper than debugging a latent defect.
How do you bake components and reset the floor life?
Baking removes absorbed moisture by holding components at elevated temperature for a defined time, after which the floor life counter can restart. Bake time and temperature depend on the package thickness, the MSL and whether the parts are in a reel, tray or tube, so always follow the bake table in J-STD-033 and the manufacturer’s datasheet.
Key practical points:
- Check the carrier first. Standard plastic tape reels, trays and tubes often cannot withstand high-temperature baking. Many parts must be moved into bake-rated trays before heating. Low-temperature baking, around 40 °C, is sometimes specified for parts that cannot tolerate more, but it takes far longer.
- Use a controlled oven. A dedicated, calibrated drying oven or dry cabinet keeps temperature and humidity within limits. A kitchen oven or hot plate is not an acceptable substitute.
- Follow the specified time. Cutting the bake short leaves residual moisture and defeats the purpose.
- Limit repeat baking. Repeated high-temperature cycles can oxidise leads and affect solderability, so keep a record of how many times each reel has been baked.
- Reseal or use promptly. After a full bake, the floor life restarts from zero. Either place the parts in a dry bag with fresh desiccant and a new humidity indicator card, or begin counting floor life again as you load them.
Specific temperatures and durations vary by part, and the exact figures should be taken from the standard and the component datasheet rather than from memory.
How should partially used MSL parts be stored between builds?
Partially used MSL parts should go back into dry storage as soon as possible, either in a sealed moisture barrier bag with fresh desiccant and a humidity indicator card, or in a dry cabinet that holds humidity at or below 10% RH. Return them within the time allowed by the remaining floor life, and note the cumulative exposure on the reel.
Good practice for storage between builds:
- Reseal quickly. Use the original bag or a new moisture barrier bag. Expel excess air, add fresh desiccant and heat-seal it.
- Replace the humidity indicator card. A used card may no longer give a trustworthy reading.
- Use a dry cabinet where reels are opened often. Dry storage at low humidity can pause the floor life clock, but the applicable rules, including how much of the floor life has already been used, come from J-STD-033.
- Label everything. Record the MSL, date opened, exposure used so far and any bake history on the reel or bag.
- Plan builds around floor life. For MSL 3 and above, avoid opening a reel for a build that cannot be completed within the remaining time.
This matters most in prototype and NPI work, where designs are revised often and the same parts get opened, used in small numbers and set aside for weeks. Tracking exposure properly prevents moisture-related defects from showing up as unexplained assembly failures.
How Eurocircuits helps with MSL component handling
Handling MSL-rated parts correctly takes time that engineers rarely have during a development cycle. Eurocircuits is a European manufacturer of PCB prototypes and low-volume assemblies, so component preparation and assembly happen in one organisation rather than being split across suppliers. This is how that helps:
- Component verification before assembly: component identities, manufacturer part numbers and packages are checked against the BOM and placement data, so problems are found before parts are used.
- Integrated PCB manufacturing and assembly: fewer hand-offs between suppliers means fewer opportunities for moisture-sensitive parts to sit exposed while waiting for boards.
- Pre-production verification: design and data issues are identified digitally, which helps reduce avoidable iterations and unnecessary repeat handling of sensitive components.
- Low-volume focus: processes are built for prototypes, NPI and small series, where partial reels and changing designs are the norm.
Please note that specific MSL handling procedures, supported component storage and bake services should be confirmed with Eurocircuits for your project. If you are planning an assembly with moisture-sensitive components and want to discuss your requirements, contact the Eurocircuits team or explore the PCB prototype and assembly services.
Related Articles
- Who offers PCB manufacturing and assembly for prototypes?
- Who can manufacture a small number of prototype PCBs and assemble them in Europe?
- Which European PCB manufacturers specialise in low volumes?
- Can you reduce assembly costs by optimizing your BOM in 2026?
- What does Right First Time mean in PCB manufacturing?